- Enerpac flow and pressure control valves are rated for 700 bar operating pressure
- All valves feature NPTF porting to insure against leakage at rated pressure
- All valves are painted, coated, or plated for corrosion resistance
- Needle valves: to control cylinder speed
V-82: can also be used as shut-off valve for temporary load holding
V-182: as V-82, also suitable for gauge snubbing
V-8F: as V-82, but with very fine metering for precise flow control. Not remommended as shut-off valve - V-91: Snubber valve, prevent snapping of gauge pointer when load or pressure is suddenly released. Also suitable as shut-off valve to protect gauge during high cycle applications
- V-10: auto damper valve; protect gauge during high cycle applications
- Check valves: for load holding with cylinders, to control oil flow direction
V-17: to resist shock and operate with low pressure drop
V-42: pilot-operated, pilot pressure ratio 14%
V-66: manually operated
V-66F: same as V-66, but with fine metering for precise oil flow control - Pressure relief valves: limits pressure in circuit developed by pump
V-152: ±3% repeatability - V-161: sequence valve; to control oil flow to a secondary circuit.